Fastening Main Shaft & Nut for HC-6S and HC-18C
Problems : The main shaft and bolt could be loose. And problems might occur.
1) Noise comes out when the nut of main shaft comes loose.
2) Plastic rotary wing could be chipped by the shaving blade because
the wing does not rotate round evenly and horizontally. Chipped plastic
might go into shaved ice.
3) The rotary wing could be locked depending on how the fastening nut comes
loose.
Procedures for trouble shooting :
1) Be sure that the power switch is off.
2) Put the stainless stopper(8mm dia pole in the hole for HC-6S, 6mm dia
pole for HC-18C) or a screw driver into the drain hole of the conical case.
The stopper will block the rotation of the wing.
3) Take out the nut fastening the rotary wing by T-wrench. (Counter-clockwise)
4) Put a new nut to fasten the rotary wing, but fasten lightly. (Clockwise)
. See the Picture-2 and confirm the stopper in the position.
5) Close the lid.
6) Turn on the power switch to rotate the rotary wing. The power (about
400KG)to rotate the wing will firmly fasten the screw of the main shaft
lower screw.
7) Open the lid, and move the rotary wing in the position of Picture-2.
8) Repeat the procedures 5) to 7) two times more (total three times of
kicks).
9) Open the lid. Fasten the nut by T-wrench by a SINGLE HAND. (Do not fasten
too strongly. Use a single hand only instead of two hands. The torque will
be less than 200 kgs.)
10) Pull out the stainless stopper from the hole, close the lid, and check
the operation.
| Change nuts |
. Picture-1 |
Picture-2 |
Stopper |
Picture-4 |
 |
 |
 |
 |
 |
|
|
Put 8ƒÓ stopper pole for HC-6S,
6ƒÓ HC-18C. |
|
|